封堵材料EN1366-3耐火测试及CE Marking/英国UKCA认证
作者:admin    发布于:2022-02-17 10:15:40    文字:【】【】【
摘要:防火封堵材料Firestop material需要符合英国及欧盟标准BS EN 1366-3的耐火测试要求,南京睿督公司提供英国UKAS资质Warringtonfire实验室所出具的Collar及Wrap型号的EN1366-3耐火测试报告,(90min,120min,150min,240min)以及封堵材料CE Marking(欧盟CE认证)及英国UKCA认证。咨询电话:025-86583475

封堵材料EN1366-3耐火测试及CE Marking
防火封堵材料Firestop material需要符合英国及欧盟标准BS EN 1366-3的耐火测试要求,南京睿督公司提供英国UKAS资质Warringtonfire实验室所出具的Collar及Wrap型号的EN1366-3耐火测试报告,(90min,120min,150min,240min)以及封堵材料CE Marking(欧盟CE认证)及英国UKCA认证。咨询电话:025-86583475

EN 1366-3耐火测试标准名称
EN 1366-3: Fire resistance tests for service installations- Part 3: Penetration seals.
EN 1366-3: 服务设施耐火测试-第3部分:穿透性密封件

EN 1366-3耐火测试方法
样品暴露在高温高压条件下,测试样品在规定时间内(30分钟、60分钟、90分钟、120分钟等)的承重量,完整性、隔热性。
 
EN 1366-3耐火测试性能评定
失去完整性:当棉垫被点燃或者背火面燃烧达10秒钟以上时,被认为试件失去完整性;测试过程中,6mm直径的探棒可穿过裂缝进入炉内且探棒可沿裂缝长度方向不小于150mm; 直径25mm的探棒可穿过裂缝进入炉内时,则被认为试件失去完整性。
 
失去隔热性: 试件背火面的平均温升超过试件表面初始平均温度140℃或者背火面在任何一点的温升超过该点初始温度180℃时,则被认为试件失去隔热性。

失去承重性:在试验过程中试件发生垮塌;或梁板构件的最大挠度、柱构件的轴向变形、柱构件的轴向变形速率超过规定值时,则被认为试件失去承重性。
 
EN 1366-3服务设施耐火测试-标准名称:
 
EN 1366-1: Fire resistance tests for service installations- Part 1: Ducts
EN 1366-1: 服务设施耐火测试-第1部分:管道

EN 1366-2: Fire resistance tests for service installations- Part 2: Fire dampers
EN 1366-2: 服务设施耐火测试-第2部分:防火阀

EN 1366-3: Fire resistance tests for service installations- Part 3: Penetration seals.
EN 1366-3: 服务设施耐火测试-第3部分:穿透性密封件
 
EN 1366-4: Fire resistance tests for service installations- Part 4: Linear joint seals.
EN 1366-4: 服务设施耐燃测试-第4部分:线性密封件
 
EN 1366-5: Fire resistance tests for service installations- Part 5: Service ducts and shafts.
EN 1366-5: 服务设施耐燃测试 - 第5部分:服务管道和竖井
 
EN 1366-6: Fire resistance tests for service installations- Part 6: Raised access and hollow core floors.
EN 1366-6: 服务设施耐燃测试 - 第6部分:高架地板和中空地板
 
EN 1366-7: Fire resistance tests for service installations- Part 7: Conveyor systems and trackbound transportation systems (in course of preparation)
EN 1366-8: Fire resistance tests for service installations- Part 8: Smoke extraction ducts
EN 1366-9: Fire resistance tests for service installations- Part 9: Single compartment smoke extraction ducts (in course of preparation).
EN 1366-10: Fire resistance tests for service installations- Part 9: Smoke control dampers  (in course of preparation)

CE Marking for Fire Collars, Wraps and Sleeves
Why our Fire Collars, Wraps and Sleeves are CE Marked?
Under The Construction Products Regulation (CPR) In July 2013 it became a legal requirement for many life safety products to be CE Marked.

To comply, products must be fixed with a CE Mark after undergoing extensive independent third party testing. Quelfire QWR Fire Collars, QWW Intuwraps and QRS Fire Sleeves have been fire tested to BS EN 1366-3: 2009 at Exova Warringtonfire and under gone durability testing. In addition continuous factory production controls and external auditing by Warrington Certification are undertaken.

This law applies to any construction product covered by a harmonised European standard (hEN). Any product which falls under a hEN but is not CE Marked can no longer be supplied or installed in the UK or the rest of Europe.

更多关于封堵材料EN1366-3耐火测试及CE Marking,请咨询南京睿督公司
南京睿督公司咨询电话:400-603-6575  025-8658 3475
网址:www.fire-test.com    www.fire-test.cn  
邮箱:info@fire-test.com
 
……



图片
版权所有 Copyright(C)2012-2015 南京睿督科技有限公司 苏公网安备 32010502010102号 苏ICP备12030029号-5
电话:025-8658 3475  传真:025-8658 3457  网址:http://www.en45545.cn/   邮箱:info@fire-test.com